All of DECRA’s products have been tested in compliance with the High-Velocity Hurricane Zone (Broward & Dade Counties) of the Florida Building Code. While not typically required outside the state of Florida, the testing methods have produced fastening schedules with maximum design uplift pressures that would be beneficial to any area that experiences high winds – particularly those along the coasts.
Please note that for testing purposes, each product is tested to twice the amount of maximum design uplift pressure noted for each of the installation options. However, the numbers are divided by 2 in testing methods to allow for a 100% safety factor. The maximum design uplift pressure is expressed in negative numbers to reflect the amount of pressure applied in an attempt to peel the metal panels away from the roof.
For Miami-Dade County, the required ratings are set out below. To view specific fastening schedules and maximum design uplift pressures for DECRA panels, please click on the desired wind rate and exposure. Within each of the wind ratings and exposures, there are five installation assemblies: on battens, on battens and counter battens, direct to deck, on steel battens and Villa direct to deck.
All DECRA products have a 120 mph wind warranty.
|
REQUIRED RATINGS for MIAMI-DADE COUNTY APPROVALS
|
|
130 MPH B Exposure
|
130 MPH C Exposure
|
140 MPH B Exposure
|
140 MPH C Exposure
|
150 MPH B Exposure
|
150 MPH C Exposure
|
|
FIELD
|
-30.4 psf
|
-42.6 psf
|
-35.3 psf
|
-49.4 psf
|
-40.5 psf
|
-56.7 psf
|
|
PERIMETER
|
-48.4 psf
|
-67.8 psf
|
-56.2 psf
|
-78.7 psf
|
-64.5 psf
|
-90.3 psf
|
|
CORNER
|
-71.6 psf
|
-100.2 psf
|
-83.1 psf
|
-116.3 psf
|
-95.4 psf
|
-133.6 psf
|
|
OVERHANG PERIMETER
|
-56.7 psf
|
-79.4 psf
|
-65.7 psf
|
-92.0 psf
|
-75.5 psf
|
-105.7 psf
|
|
OVERHANG CORNER
|
-95.3 psf
|
-133.4 psf
|
-110.6 psf
|
-154.8 psf
|
-126.9 psf
|
-177.7 psf
|
Miami Dade County:
Miami Dade County NOA#09-0610.02 Tile, Villa Tile, Shake, Shake XD, Shingle Plus
FL Approvals:
Approval #9759.R2 Tile, Shake, Shingle Plus (battens)
Evaluation Report #9759.R2 Tile, Shake, Shingle Plus (battens)
Approval #11255.R2 Villa Tile, Shake XD, Shingle Plus (direct to deck)
Evaluation Report #11255.R2 Villa Tile, Shake XD, Shingle Plus (direct to deck)
Click here for areas outside of the High-Velocity Hurricane Zone (HVHZ), or you can follow the fastening schedules set out within the HVHZ requirements.